Practical Skills & Uncertainties

Units 3 and 6 are written papers about experiments. There's no practical exam, but you get questions on planning an experiment, taking readings, spotting what an inexperienced student did wrong, and processing real results. The skills on this page are the same for every topic, so learning them once picks up marks in every unit.

Unit 3 (WPH13)

Practical skills from Units 1 and 2: planning, implementing and processing results. You need percentage uncertainties from a single reading or from repeats, but you are not expected to combine (compound) uncertainties.

Unit 6 (WPH16)

The same skills applied to Units 4 and 5, plus compounding percentage uncertainties, logarithmic graphs, and the words precision, accuracy and sensitivity.

The language of measurement

Edexcel uses these words in a precise, scientific way (from the ASE's The Language of Measurement). Exam answers that use them loosely, like "the results were accurate because I repeated them", lose marks. Repeating improves precision, not accuracy.

TermWhat it means
ValidityA measurement is valid if it measures what it is supposed to be measuring. This depends on both the method and the instruments.
True valueThe value you'd get from an ideal measurement. Apart from fundamental constants, it is considered unknowable.
AccuracyHow close a result is judged to be to the true value. It can't be given a number, and it is affected by both random and systematic errors.
PrecisionHow closely repeated measurements agree with each other (how tightly they cluster). Only random effects affect it.
RepeatabilityPrecision when the same person uses the same method and equipment over a short time.
ReproducibilityPrecision when different people use different apparatus or methods. A harder test than repeatability.
UncertaintyThe interval within which the true value can be considered to lie, e.g. 20 °C ± 2 °C.
ErrorThe difference between the measurement and the true value. It is not a mistake.
ResolutionThe smallest measuring interval of an instrument, and the source of uncertainty in a single reading.

Random and systematic errors

Readings scatter unpredictably either side of the true value: reaction time with a stopwatch, a fluctuating meter, judging when a pendulum passes a point. They reduce precision.

Reduce it by repeating and averaging, timing many oscillations rather than one, or using a light gate or data logger instead of a human.

Every reading is wrong by the same amount or the same proportion in the same direction: a zero error, a stretched tape measure, always reading a scale from above (parallax), heat lost to the surroundings. They reduce accuracy, and repeating does not help at all.

Reduce it by checking zero before you start, calibrating, and using a set square or eye-level reading to avoid parallax. Using a graph's gradient also cancels a constant offset.

Reading instruments

You need to know the resolution of the instruments you'd choose. A metre rule reads to 1 mm, vernier calipers to 0.1 mm and a micrometer screw gauge to 0.01 mm. In the exam you may be shown a picture of one and asked for the reading to the correct number of significant figures.

InstrumentResolutionTypical use
Metre rule1 mmLengths of a pendulum or wire, heights, extensions over 1 cm
Vernier calipers0.1 mmDiameter of a ball bearing or cylinder, internal diameters, depths
Micrometer screw gauge0.01 mmDiameter of a wire (CP3, CP7), thickness of a sheet
Stopwatch0.01 s (but human reaction time ≈ 0.1–0.3 s)Timing 10 or 20 oscillations
Light gate + data logger~0.001 sShort times and speeds (CP1, CP9)
Digital metersthe last digit shownCurrent, p.d., mass (top-pan balance)

Vernier calipers

The sliding vernier scale has 10 divisions that span 9 mm, so each one is 0.9 mm long. Every vernier line is 0.1 mm shorter than a main-scale millimetre, so when the jaws open by an extra 0.1 mm, the next vernier line lines up with a main-scale line. To read it:

  1. Read the main scale at the vernier's zero: whole millimetres.
  2. Find the vernier line that lines up exactly with a main-scale line. Its number is the tenths of a millimetre.
  3. Add them, and check the zero reading with the jaws closed (zero error).

Micrometer screw gauge

One full turn of the thimble moves the spindle 0.50 mm, and the thimble has 50 divisions, so each division is 0.01 mm. Read the sleeve (millimetres and the half-millimetre marks below the line) and add the thimble division on the datum line × 0.01 mm. Always use the ratchet so you don't squash the wire, and check the zero.

When measuring a wire's diameter, take readings at several places along the wire and at right angles to each other (in case it isn't perfectly round), then average. Write it in the method; it's an easy mark in almost every planning question.

Uncertainties

Uncertainty in a single reading or in repeats

Percentage uncertainty

\[ \text{percentage uncertainty} = \frac{\text{uncertainty}}{\text{measured value}} \times 100\% \]
Usually quoted to 1 or 2 significant figuresBelow about 5% suggests the measurement is repeatable
Worked example

The diameter of a canister is measured three times with a ruler: 66 mm, 64 mm and 61 mm. Give the diameter with its uncertainty and its percentage uncertainty.

Show solution

Mean = (66 + 64 + 61)/3 = 63.7 mm. To the resolution of the ruler that's 64 mm.

\[ \text{uncertainty} = \tfrac{1}{2}(\text{range}) = \tfrac{1}{2}(66 - 61) = 2.5\ \text{mm} \] \[ \text{percentage uncertainty} = \frac{2.5}{64} \times 100\% = 3.9\% \approx 4\% \]

So the diameter is 64 mm ± 2.5 mm (± 4%). The radius has the same percentage uncertainty, 4%, even though its absolute uncertainty is halved to 1.25 mm.

Combining uncertainties Unit 6

When you calculate something from several measurements, their uncertainties combine. There are just three rules:

Adding or subtracting

Add the absolute uncertainties.

\[ (102.8 \pm 0.3) - (101.4 \pm 0.1) = 1.4 \pm 0.4\ \text{mm} \]
Multiplying or dividing

Add the percentage uncertainties.

\[ \%\,\rho = \%\,m + \%\,V \]
Raising to a power

Multiply the percentage uncertainty by the power.

\[ \%(d^2) = 2 \times \%\,d \]

Subtracting two nearly equal measurements is dangerous: the absolute uncertainties still add, but the result is small, so its percentage uncertainty is huge. In the pipe example above, 0.4 mm on 1.4 mm is a 29% uncertainty from two readings that were each better than 0.3%.

Recording results and significant figures

A student times 10 oscillations of a pendulum four times: 15.2 s, 15.6 s, 15.3 s and 15.5 s. What is the period, with its uncertainty?

Mean of 10T = 15.4 s with half-range uncertainty (15.6 − 15.2)/2 = 0.2 s. Dividing by 10 gives T = 1.54 s ± 0.02 s. Timing 10 oscillations divides the reaction-time uncertainty by 10, which is exactly why we do it.

Straight-line graphs

Almost every experiment ends with a straight-line graph, because a straight line is easy to recognise, a line of best fit averages out random error, and its gradient and intercept give you the constant you're after. The trick is to rearrange the physics equation into the form

\[ y = m\,x + c \]

and then plot whatever plays the role of \(y\) against whatever plays the role of \(x\).

EquationPlot yagainst xGradientIntercept
\(h = \tfrac{1}{2}gt^2\) (CP1)\(h\)\(t^2\)\(g/2\)0
\(R = \rho l / A\) (CP7)\(R\)\(l\)\(\rho/A\)0 (contact resistance if not)
\(V = \varepsilon - Ir\) (CP8)\(V\)\(I\)\(-r\)\(\varepsilon\)
\(T = 2\pi\sqrt{m/k}\) (CP16)\(T^2\)\(m\)\(4\pi^2/k\)0
\(pV = NkT\) at fixed \(T\) (CP14)\(p\)\(1/V\)\(NkT\)0
\(V = V_0 e^{-t/RC}\) (CP11)\(\ln V\)\(t\)\(-1/RC\)\(\ln V_0\)

Logarithmic graphs Unit 6

Two kinds of relationship can't be straightened just by squaring or inverting, because you don't know the power yet, or the variable sits in an exponent. Taking logs turns both into straight lines.

Take logs (base 10 or base e, as long as you are consistent) of both sides:

\[ \log y = \log(k x^n) \]

Use \(\log(ab) = \log a + \log b\) and \(\log(x^n) = n\log x\):

\[ \log y = n\,\log x + \log k \]

Compare with \(y = mx + c\): plotting \(\log y\) against \(\log x\) gives a straight line with

\[ \text{gradient} = n, \qquad \text{intercept} = \log k \]

So a log–log graph tells you the power directly. For example, plotting \(\log T\) against \(\log l\) for a pendulum gives a gradient of 0.5.

Take natural logs (base e) of both sides:

\[ \ln y = \ln\!\left(A e^{-kx}\right) = \ln A + \ln\!\left(e^{-kx}\right) \]

Since \(\ln(e^{z}) = z\):

\[ \ln y = -k\,x + \ln A \]

Plot \(\ln y\) against \(x\) (only \(y\) is logged): a straight line with gradient \(-k\) and intercept \(\ln A\). This is how you get the time constant from capacitor discharge (CP11) and the decay constant in radioactivity.

Logs have no units, so label the axis ln (V / V) or log (T / s): take the log of the number, not the unit. When reading a gradient on a log graph, use differences in the log values on the axes, not the original numbers.

Drawing conclusions

To decide whether your result is accurate, compare it with the accepted value in one of two ways:

If you know the percentage uncertainty

Work out the range your result could lie in. If the accepted value is inside it, the result is accurate. Example: \(g = 10.1\ \text{m s}^{-2} \pm 4\%\) means 9.7 to 10.5 m s⁻², which includes 9.81, so it's accurate.

If you don't (e.g. a value from a gradient)

Find the percentage difference. Less than 5% indicates the result is accurate.

\[ \frac{10.1 - 9.81}{9.81}\times 100\% = 3\% \]

Then go further than "it was accurate". Say which measurement had the largest percentage uncertainty, and suggest a specific improvement: "use a micrometer instead of a ruler for the diameter", not "use better equipment". Mention any systematic error suggested by a non-zero intercept.

Planning an experiment

Planning questions are marked against a checklist. Hit every point:

  1. Variables: state the independent variable (what you change), the dependent variable (what you measure) and every control variable, with how each is kept constant.
  2. Apparatus with resolution: name each instrument and its resolution, chosen to suit the size of the measurement (micrometer for a wire, metre rule for its length).
  3. Method: how each variable is measured, including technique details (eye level to avoid parallax, set square, fiducial marker at the centre of an oscillation, timing 20 oscillations, checking zero).
  4. Range and repeats: at least 6 values over a wide range, repeated and averaged where readings vary.
  5. Analysis: which graph you'll plot and how the gradient or intercept gives the answer.
  6. Sources of uncertainty and how to reduce them, plus any safety issue with a sensible precaution (goggles when wires may snap, a sand tray under hanging masses, lead-lined handling tongs for sources).

The 16 core practicals

Each one is covered on its topic page with a virtual version you can run. Click through to revise the method and analysis.

#Core practicalKey graph or analysis
1Acceleration of a freely-falling object\(h\) against \(t^2\), gradient \(= g/2\)
2Viscosity of a liquid by the falling-ball methodTerminal velocity from time between marks, then Stokes' law
3Young modulus of a materialStress against strain, gradient \(= E\)
4Speed of sound with a 2-beam oscilloscopeMove the microphone through whole wavelengths, then \(v = f\lambda\)
5Frequency of a vibrating string: length, tension, mass per unit length\(f\) against \(1/l\), or \(f\) against \(\sqrt{T}\)
6Wavelength of light with a diffraction grating\(n\lambda = d\sin\theta\) for several orders
7Resistivity of a material\(R\) against \(l\), gradient \(= \rho/A\)
8E.m.f. and internal resistance of a cell\(V\) against \(I\): intercept \(\varepsilon\), gradient \(-r\)
9Force and change of momentumImpulse \(F\Delta t\) compared with \(\Delta p\)
10Collisions between small spheres using ICTMomentum components before and after
11Capacitor charge and discharge on an oscilloscope or data logger\(\ln V\) against \(t\), gradient \(= -1/RC\)
12Calibrate a thermistor in a potential divider as a thermostatCalibration curve of \(V_\text{out}\) against temperature
13Specific latent heat of a phase change\(L = \Delta E / \Delta m\)
14Pressure and volume of a gas at fixed temperature\(p\) against \(1/V\), a straight line through the origin
15Absorption of gamma radiation by leadCorrected count rate against thickness
16Unknown mass from resonant frequencies of known masses\(T^2\) (or \(1/f^2\)) against \(m\)

Quick checks

A metre rule has a zero error: it reads 2 mm when it should read zero. What kind of error is this, and what should you do?

A zero error shifts every reading by the same amount in the same direction, so it is systematic. You correct each reading. Repeating can't remove it.

A wire's diameter is measured as 0.50 mm ± 0.01 mm. What is the percentage uncertainty in its cross-sectional area?

% uncertainty in \(d\) = 0.01/0.50 × 100% = 2%. Area \(= \pi d^2/4\), so the percentage doubles to 4%. π and the 4 are exact numbers with no uncertainty.

The intensity of a source falls with distance as \(I = k d^n\). Which graph gives \(n\) as its gradient?

\(\log I = n\log d + \log k\), a straight line with gradient \(n\). Plotting \(I\) against \(1/d^2\) only works if you already know that \(n = -2\).

A student repeats a measurement many times and gets very similar values, but they are all well away from the accepted value. The results are best described as:

Close agreement between repeats means precise. Being far from the true value means not accurate, which points to a systematic error.

Interactive diagrams

Set the random spread near zero and raise the systematic offset: the readings are precise but not accurate. Then do the opposite; more readings shrink the uncertainty in the mean but never remove a systematic offset.
Drag the slider to open the jaws and read the calipers yourself, then tick "Show the reading" to check. The green line marks the vernier line that lines up with the main scale.
Move the slider to turn the thimble and read the micrometer, then tick "Show the reading" to check. Under More settings, switch on the zero error: it reads +0.03 mm with the jaws closed, so subtract 0.03 mm from every reading.
With the resistivity calculation chosen, make the wire thinner: the diameter is squared, so its percentage uncertainty counts twice and soon becomes the biggest bar. Tick the cheaper instruments to see why we measure diameter with a micrometer, not a ruler.
Drag the two white handles to put the best straight line through the points by eye, then tick "Show least-squares line" to compare. The orange triangle is the large gradient triangle you would draw in the exam.
Choose a relationship and compare the raw graph with the straightened one. Change the power \(n\) for the power law: the raw curve changes shape, but the log–log graph stays straight and only its gradient changes.